Orbisphere GA2400 Stainless Steel Oxygen Sensor (EC) for 6110 TPO Analyser, 40 bar, EPDM O-rings

Orbisphere GA2400 Stainless Steel Oxygen Sensor (EC) for 6110 TPO Analyser, 40 bar, EPDM O-rings
Product #: GA2400-S00T
Unit Price Contact Hach
Available

Easy and fast maintenance

Traditional cleaning processes can take more than thirty minutes to complete. The GA2400 and GA2800 EX come with an innovative cartridge system that contains everything needed to complete membrane and electrolyte solution change in less than 5 minutes.

Low level oxygen measurement and unrivaled accuracy

The Hach Orbisphere GA2400 and GA2800 EX utilise an electrochemical oxygen sensor with a lower detection level of 0.1 ppb and unrivaled highly accurate readings of ±1%. This feature allows users to ensure control of low oxygen levels, for product and equipment integrity and avoiding corrosion.

Robust for harsh environments

The robust stainless steel or Hastelloy design makes the GA2400 and GA2800 EX sensor ideal for the most demanding applications. ATEX certification comes standard in all GA2800 units, making the sensor especially suitable for harsh chemical environments.

What's included?

Oxygen Sensor (GA2400-S00T), incl. plastic screw-on storage cap for sensor head protection; protection cap without grille (33051-S0); protection cap with grille (33051-SP)

Specifications

Accuracy: Accuracy = Trueness (ISO 57251)
2935A-A: The greater of ±1% of reading or ± 10 ppb, or ± 20 Pa
2952A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa
2956A-A: The greater of ±1% of reading or ± 0.1 ppb¹, or ± 1 ppb², or ± 0.25 Pa
29552A-A: The greater of ±1% of reading or ± 2 ppb, or ± 5 Pa

¹ Accuracy is ± 0.1 ppb for 410, 510, 362x, 360x and 3655 instruments
² Accuracy is ± 1 ppb for 366x and 3650 instruments
Body Material: Stainless Steel
Certifications: CE
Flow Rate: Recommended flow rate in flow chamber
2935A-A: 25 mL/min
2952A-A: 50 mL/min
2956A-A: 180 mL/min
29552A-A: 50 mL/min
Material: O-Rings: EPDM
Model: GA2400
Pressure Range: 40 bar
Pressure resistance: 40 bar minimum with default PPS collar (100 bar with stainless steel collar)
Protection Class: IP66
Range: Range at 25 °C
2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa
2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa
2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa
29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
Response Time: Response time at 25 °C for a 90% signal change
2935A-A: 2.5 min
2952A-A: 38 s
2956A-A: 7.2 s
29552A-A: 90 s
Sensor material: Stainless Steel for 6110
Temperature Compensation: -5 - 60 °C
Temperature resistance: -5 - 100 °C
Warranty: 6 months
Weight: 0.3 kg
Wetted Materials: Stainless Steel 1.4404 (AISI 316L)
No O-rings are in contact with the sample
What's included?: Oxygen Sensor (GA2400-S00T), incl. plastic screw-on storage cap for sensor head protection; protection cap without grille (33051-S0); protection cap with grille (33051-SP)