Intellical ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m cable

Intellical ISENH3181 Ammonia (NH₃) Ion Selective Electrode (ISE), 1 m cable
Product #: ISENH318101
Unit Price Contact Hach
Ships within 1 week

Provides fast, stable, and accurate results

Refillable outer body, an easy to maintain modular membrane design, and a large annular reference junction for maximum surface area between sample and reference electrolyte provide great measurement stability. Intellical digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number.

Ultimate traceability in measurement history

Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number

User alerted when re-calibration is needed

No guesswork needed to provide most reliable and accurate results with each measurement.

Can be moved between meters without the need to re-calibrate or re-enter measurement settings

Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters

What's included?

Intellical ISENH3181 combination Ammonia ISE, 1 m cable (ISENH318101), 3-pack of replacement Intellical ammonia membrane modules (no. 5812711), a 50 mL bottle of electrode fill solution (no. 4447226), Test certificate, and Basic User Manual.

Specifications

Accuracy: ±0.02 mV or 0.05%, whichever is greater
Cable Length: 1 m
Electrode Type: Non-Refillable Gel Reference Element,
Replaceable membrane
  Standard
Filling Solution: 0.1 M NH4Cl
(#4447226)
ISA Required: Ammonia ISA
(#4447169)
Junction: Double Annular Junction
Kit?: No
Length: 175 mm
Method Type: Laboratory: Non-Refillable Gel Reference Element, Replaceable membrane
Parameter: Ammonia
Product Kit: Model: ISENH381
Accessories Included: None
Range: 0.01 mg/L (5 x 10-7 M) - 14 g/L (1 M) NH3-N
Reference system: Ag/AgCl
Resolution: Selectable up to 4 significant digits
Sample Volume: 15 mL
Sensor material: Epoxy
Sensor Type : pH Glass with replaceable NH₃ sensitive membrane
Special Features: Easy-to-replace membrane modules.
Temperature Accuracy: ±0.3 °C
Temperature Range: 5 - 50 °C
Temperature resolution: 0.1 °C
Test requirements: Parameter Needed: Ammonia
Minimum Sample Depth (mm): 26
Thermistor : ATC
Warranty: 6 months
Weight: 0.1 kg
What's included?: Intellical ISENH3181 combination Ammonia ISE, 1 m cable (ISENH318101), 3-pack of replacement Intellical ammonia membrane modules (no. 5812711), a 50 mL bottle of electrode fill solution (no. 4447226), Test certificate, and Basic User Manual.