Ambient Temperature:
                                            
                                            
                                        
									    5 to 40 °C (41 to 104°F)
Air conditioning and heating options are available.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Communication: digital:
                                            
                                            
                                        
									    Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol)
Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available
                                    
                                
    						
								
                                    
                                        
                                            
                                                Cycle Time:
                                            
                                            
                                        
									    From 6.5 minutes, depending on range and application
                                    
                                
    						
								
                                    
                                        
                                            
                                                Data storage:
                                            
                                            
                                        
									    Previous 9999 analysis data on screen in the microcontroller memory and storage of data archive for the lifetime of the analyser in the SD/MMC card.
Previous 99 fault data on screen in the microcontroller memory and storage of fault data archive for the lifetime of the analyser in the SD/MMC card.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Display:
                                            
                                            
                                        
									    High contrast 40 character x 16 line backlit LCD with CFL backlight
                                    
                                
    						
								
                                    
                                        
                                            
                                                Drain Pressure:
                                            
                                            
                                        
									    Typically ambient (for applications with high drain pressure, optional systems are available)
                                    
                                
    						
								
                                    
                                        
                                            
                                                EExp / Hazardous Location:
                                            
                                            
                                        
									    Certification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1
                                    
                                
    						
								
                                    
                                        
                                            
                                                Enclosure rating:
                                            
                                            
                                        
									    IP44; optional IP54 with air purge
                                    
                                
    						
								
                                    
                                        
                                            
                                                Exceedance tracking:
                                            
                                            
                                        
									    Full exceedance tracking to maximum range
                                    
                                
    						
								
                                    
                                        
                                            
                                                Expected Measuring Range:
                                            
                                            
                                        
									    High range > 5000 mg/L
                                    
                                
    						
								
                                    
                                        
                                            
                                                Humidity:
                                            
                                            
                                        
									    5 - 85 % , non-condensing
                                    
                                
    						
								
                                    
                                        
                                            
                                                Languages user interface:
                                            
                                            
                                        
									    English
                                    
                                
    						
								
                                    
                                        
                                            
                                                Lower Limit of Detection (LOD):
                                            
                                            
                                        
									    0.6 mg/L C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measurement method:
                                            
                                            
                                        
									    Infrared measurement of CO2 after oxidation
                                    
                                
    						
								
                                    
                                        
                                            
                                                Measuring range:
                                            
                                            
                                        
									    0 - 20000 mg/L C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Multi-Stream:
                                            
                                            
                                        
									    1, 2, 4 and 6 streams
                                    
                                
    						
								
                                    
                                        
                                            
                                                Number of Channels:
                                            
                                            
                                        
									    1
                                    
                                
    						
								
                                    
                                        
                                            
                                                Number of streams:
                                            
                                            
                                        
									    1
                                    
                                
    						
								
                                    
                                        
                                            
                                                Outputs:
                                            
                                            
                                        
									    4 - 20 mA
                                    
                                
    						
								
                                    
                                        
                                            
                                                Oxidation Method:
                                            
                                            
                                        
									    Patented Two-Stage Advanced Oxidation Process using Hyroxyl Radicals
                                    
                                
    						
								
                                    
                                        
                                            
                                                Parameter:
                                            
                                            
                                        
									    TOC, TIC, TC, VOC, after correlation COD, BOD
                                    
                                
    						
								
                                    
                                        
                                            
                                                Particle Size:
                                            
                                            
                                        
									    Up to 2 mm, soft particulates
                                    
                                
    						
								
                                    
                                        
                                            
                                                Permissible Chloride range:
                                            
                                            
                                        
									    Up to 30%
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Hz):
                                            
                                            
                                        
									    60 Hz
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    115 VAC
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power supply:
                                            
                                            
                                        
									    TOC/TIC (115VAC)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range selection:
                                            
                                            
                                        
									    Automatic or Manual Range Selection
                                    
                                
    						
								
                                    
                                        
                                            
                                                Repeatability:
                                            
                                            
                                        
									    ± 3 % of reading or ± 0.3 mg/L C, whichever is greater, with Automatic Range Selection
                                    
                                
    						
								
                                    
                                        
                                            
                                                Response time:
                                            
                                            
                                        
									    TOC 6.5 minutes
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Inlet Temperature:
                                            
                                            
                                        
									    2 - 60 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Volume:
                                            
                                            
                                        
									    Up to 8.0 mL
                                    
                                
    						
								
                                    
                                        
                                            
                                                Service Interval:
                                            
                                            
                                        
									    6 months service intervals
                                    
                                
    						
								
                                    
                                        
                                            
                                                User Interface:
                                            
                                            
                                        
									    Microcontroller with membrane keyboard
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    90 - 120 kg
Enclosure weight may change depending on system optional features.
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    Includes: B7000i Analyser, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, CO₂ Filter & B7000i User Manual