Chemistries, Reagents and Standards

Chemistries, Reagents and Standards
Hach has more than 60 years of history dedicated to formulating and packaging high-quality reagents for water analysis. We understand your applications and formulate our reagents to ensure exceptional performance and deliver results you can trust, time after time. Our expertise extends beyond chemistry formulation to the complete reagent system. Hach chemistries are rigorously tested in combination with our packaging and instruments to ensure the highest possible system performance. No other company can offer these advantages.
 
Browse Products by Parameter

Products: Chlorine, Total

Instrument, Test Kit, etc
ZAR Price
34932: Starch indicator solution, 100 mL MDB Solution 0 - 40,000 mg/L 8161 WAH, Iodometric Buret Titration     Contact Hach
Solution 20 - 2,000 mg/L Cl₂ 8209 Iodometric Method   View
Solution 20 70,000 mg/L 8209 WAH, Iodometric, Digital Titration   View
Solution 0 - 400 mg/L 8161    
Solution 1 - 400 mg/L Cl₂ 8209 WAH, Iodometric, Digital Titration   View
Solution 2,000 - 70,000 8209 Iodometric Method   View
2263511: Total chlorine buffer solution for chlorine analyser CL17/CL17sc (473 mL) Solution 0.02 - 2.00 mg/L Cl₂ 10060 DPD Rapid Liquid, Pour-Thru Cell     Contact Hach
2263411: Total chlorine indicator solution for chlorine analyser CL17/CL17sc (473 mL) Solution 0.02 - 2.00 mg/L Cl₂ 10060 DPD Rapid Liquid, Pour-Thru Cell     Contact Hach
2641549: Dilution water, organic free, 500 mL Solution 0.02 - 2.00 mg/L Cl₂ 8167 DPD Powder Pillows or AccuVac® Y View Contact Hach
Solution 0.05 4.00 mg/L Cl2 10250 DPD Powder Pillows Y  
1426810: Chlorine standard solution, 50-75 mg/L Cl₂ Solution 20 70,000 mg/L 8209 WAH, Iodometric, Digital Titration   View Contact Hach
Solution 0.05 2.00 mg/L 10232 Spectrophotometer DPD TNTplus DPD Y  
Solution 0.003 - 5 mg/L Cl₂ AT1000 Amperometric Forward Titration Automatic Titrator Method    
Solution 0.02 - 2.00 mg/L Cl₂ 10060 DPD Rapid Liquid, Pour-Thru Cell    
Solution 0.1 - 10.0 mg/L as Cl₂ 10070 DPD Powder Pillows Y View
Solution 0.005 - 5 mg/L Cl₂ AT1000 Amperometric BackwardTitration Automatic Titrator Method    
Solution 0.05 4.00 mg/L Cl2 10250 DPD Powder Pillows Y  
Solution 2,000 - 70,000 8209 Iodometric Method   View
Solution 2 - 500 µg/L ULR as Cl₂ 8370 DPD Y  
Solution 0.5 mg/L and above 8168 WAH, Amperometric Buret Titration Y  
Solution 0.0012 - 5,000 mg/L Cl₂ 8168 Amperometric Buret Titration Method Y  
Solution 20 - 2,000 mg/L Cl₂ 8209 Iodometric Method   View
Solution 1 - 400 mg/L Cl₂ 8209 WAH, Iodometric, Digital Titration   View
Solution 0.02 - 2.00 mg/L Cl₂ 8167 DPD Powder Pillows or AccuVac® Y View
Solution 0.1 - 8.0 mg/L Cl2 DPD HR PCII DR300 SwifTest Dispenser    
Solution 0.09 - 5.00 mg/L Cl₂ 10101 DPD Test 'N Tube    
1426820: Standard Solution, chlorine, 50-75 mg/L as Cl2, pk/20 - 2 mL PourRite ampules Solution 15 - 1,000 µg/L Cl₂ 10026 WAH, Digital Titration Amperometric Forward Titration Y View Contact Hach
Solution 0.02 - 2.00 mg/L Cl₂ 8167 DPD Powder Pillows or AccuVac® Y View
Solution 0 10.0 mg/L Cl2 10070 DR900, DPD Powder Pillows DPD Y  
Solution 2 - 500 µg/L ULR as Cl₂ 8370 DPD Y  
Solution 0.02 - 2.00 mg/L Cl₂ 10060 DPD Rapid Liquid, Pour-Thru Cell    
Solution 0.0012 - 5,000 mg/L Cl₂ 8168 Amperometric Buret Titration Method Y  
Solution 6 - 1,000 µg/L Cl₂ 10025 WAH, Digital Titration Y View
Solution 0.05 4.00 mg/L Cl2 10250 DPD Powder Pillows Y  
Solution 0.5 mg/L and above 8168 WAH, Amperometric Buret Titration Y  
Solution 0.1 - 8.0 mg/L Cl2 DPD HR PCII DR300 SwifTest Dispenser    
Solution 0.05 2.00 mg/L 10232 Spectrophotometer DPD TNTplus DPD Y  
Solution 0.1 - 10.0 mg/L as Cl₂ 10070 DPD Powder Pillows Y View
Solution 0.09 - 5.00 mg/L Cl₂ 10101 DPD Test 'N Tube    
32353: Sodium thiosulfate standard solution, 0.1 N, 1 L Solution 0 - 40,000 mg/L 8161 WAH, Iodometric Buret Titration     Contact Hach
Solution 0 - 400 mg/L 8161    
2630020: Chlorine standard solution, 25-30 mg/L Cl₂, 20 pcs. Solution 0.05 4.00 mg/L Cl2 10250 DPD Powder Pillows Y   Contact Hach
Solution 0.05 2.00 mg/L 10232 Spectrophotometer DPD TNTplus DPD Y  
Solution 0 4.00 mg/L 10250 DR800, DPD Powder Pillows Y  
Solution 2 - 500 µg/L ULR as Cl₂ 8370 DPD Y  
Solution 0.003 - 5 mg/L Cl₂ AT1000 Amperometric Forward Titration Automatic Titrator Method    
Solution 0.1 - 10.0 mg/L as Cl₂ 10070 DPD Powder Pillows Y View
Solution 2 500 µg/L ULR as Cl2 10014 DPD   View
Solution 0.02 - 2.00 mg/L Cl₂ 10060 DPD Rapid Liquid, Pour-Thru Cell    
Solution 0.0012 - 5,000 mg/L Cl₂ 8168 Amperometric Buret Titration Method Y  
items per page 10   |   20   |   50