Alarm:
1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Ambient Temperature:
10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Analogue Outputs:
Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Automatic cleaning:
Yes
Calibration:
Automatic, 2-point; frequency freely programmable
Certifications:
CE compliant / UL certified
Cycle Time:
20 minutes Total Cr (dilution + 5 min.)
30 minutes Total Cr & Cr(VI)
Demineralised water:
For rinsing / dilution
Digital outputs:
Optional: Modbus (TCP/IP, RS485)
Dimensions (H x W x D):
690 mm x 465 mm x 330 mm
Drain:
Atmospheric pressure, vented, min. Ø 32 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferences:
Iron (III), mercury > 200 mg/L, molybdenum > 200 mg/L, vanadium > 5 mg/L. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Lower Limit of Detection (LOD):
Total Chromium, Cr(VI): ≤ 2 µg/L
Cr(III): ≤ 5 µg/L
Material:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Measurement method:
Colorimetric measurement at 546 nm using diphenylcarbazide method, conform with standard method APHA 3500-Cr (B)
Measuring range:
Total Cr, Cr(VI): 10 - 500 µg/L
Cr(III): 20 - 500 µg/L
Optional:
2 - 50 µg/L | Cr(III): 5 - 50 µg/L
4 - 125 µg/L | Cr(III): 10 - 125 µg/L
5 - 250 µg/L | Cr(III): 10 - 250 µg/L
0.16 - 2 mg/L | Cr(III): 0.32 - 2 mg/L (with internal dilution)
0.32 - 5 mg/L | Cr(III): 0.64 - 5 mg/L (with internal dilution)
Model:
EZ2400
Number of sample streams:
1, 2, 4 or 8
Parameter:
Chromium, total; Cr(VI), dissolved; Cr(III), dissolved
Power:
230 VAC, 50/60 Hz
120 VAC, 50/60 Hz
Max. power consumption: 440 VA
Precision:
Better than 2% full scale range for standard test solutions
Protection Class:
Analyser cabinet: IP44 / Panel PC: IP65
Range:
Total Cr, Cr(VI): 10 - 500 µg/L Cr(III): 20 - 500 µg/L
Reagent requirements:
Keep between 10 - 30 °C
Sample Flow Rate:
100 - 300 mL/min
Sample Pressure:
By external overflow vessel
Sample Quality:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Sample Temperature:
10 - 30 °C
Validation:
Automatic; frequency freely programmable
Warranty:
12 months
Weight:
25 kg
What's included?:
EZ2400 Chromium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Acid, Buffer, Persulfate) and 1 x Assembly Glass Reagent Container 2.5L (for Colour Solution)