Alarm:
Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Automatic Shutdown:
Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected)
Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Base Configuration:
Portable Standard
Base Type:
Standard
Body material:
Impact resistant ABS plastic, 3-section construction Double-walled base with 2.54 cm insulation, direct ice contact with bottles (Sampler)
Bottle Set:
Discrete (24) 1L polyethylene bottle kit for standard base
Certifications:
CE, UL
Communication Capabilities:
USB and optional RS485 (Modbus)
Data logging:
SAMPLE HISTORY - Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).
MEASUREMENTS - Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.
EVENTS - Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
Diagnostics:
View event and alarm logs as well as maintenance diagnostics
Display:
1/4 VGA, Colour; self-prompting/menu-driven program
Factory Installed Options:
Please contact your Hach sales representative for details.
NON-CONTACT LIQUID DETECT
Sample volume accuracy for applications that require complete tubing replacement
RAIN/RS485 PORT
Accepts Hach Rain Gauge (not included) or can be used as RS485 communications
TWO SENSOR PORTS
Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors
Housing Material:
PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
Inputs:
One 0/4-20 mA input for flow pacing
Intake:
Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Purge: Air purged automatically before and after each sample;
duration automatically compensates for varying intake line lengths
Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses
Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Internal Clock:
±1 second per day at 25 °C
Languages user interface:
en, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko
Lock Function:
Access code protection prevents tampering
Manual Sampling:
Initiates a sample collection independent of program in progress
Memory:
Sample history: 4000 records;
Data log: 325,000 records;
Event log: 2000 records
Operating Mode:
Continuous or non-continuous
Power requirements (Voltage):
230 V Power Supply
Power supply:
230V, 3 pin to sampler. EU plug.
Probes included:
No
Programs:
Dual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
Pump flow rate:
4.8 L/min at 1 m vertical lift with 3/8" intake tube typical
Rain Gauge Enabled:
None
Rain Gauge Input:
No
Sample Container:
24 x 1 L
Sample Interval:
Selectable in single increments from 1 to 9999 flow pulses or 1 to 9999 mins in one minute increments
Sample Pump:
High-speed peristaltic, dual roller, with 0.95 ID x 1.6 OD cm (3/8" ID x 5/8" OD) pump tube
Sample Transport Velocity:
0.9 m/s with 4.6 m vertical lift, 4.8 m of 3/8" Vinyl intake tubing, 21 °C and 1524 m elevation
Sample Trigger:
When equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
Sample Volume:
Programmable in 10 mL increments from 10 - 10,000 mL
Sample Volume Accuracy:
Typical: ±5% of 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8" Vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m elevation
Sample Volume Repeatability:
Typical: ±5% of 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8" Vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m elevation
Sampling Mode:
Pacing: Time weighted, Flow weighted, Time table, Flow table, Event
Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
Sensor Ports:
None
Sensors:
None
Status Messages:
Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Suction Hose Outer Diameter:
1/4" and 3/8" ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
Temperature:
Operating: 0 - 49 °C
Storage: -40 - 60 °C
Tubing:
Vinyl - 25', 3/8" ID x 5/8" OD tubing and PTFE/stainless steel strainer
User Interface:
Membrane switch keypad with 2 multiple function soft keys
Vertical Lift:
8.5 m using 8.8 m maximum of 3/8" Vinyl intake tube at sea level at 20 to 25 °C
Warranty:
12 months
Weight:
15 kg
What's included?:
1 ea. AS950 controller on standard portable base
1 ea. 230 V power supply (8754500EU)
1 ea. Bottle kit (PS241000), includes 24 x 1 L PE bottles w/caps (737), retainer (1422) and distributor arm (8582)
1 ea. 7 m vinyl intake tubing (920)
1 ea. strainer (926)