Alarm:
Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Base Configuration:
115V base with lock
Base Type:
No controller compartment heater
Bottle Set:
Composite 5.5 gallon polyethylene bottle kit
Communication Capabilities:
USB and optional RS485 (Modbus)
Data logging:
SAMPLE HISTORY - Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).
MEASUREMENTS - Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.
EVENTS - Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
Display:
1/4 VGA, Color; self-prompting/menu-driven program
Housing Material:
PC/ABS blend, NEMA 6, IP68, corrosion and ice resistant (Controller)
Intake:
Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Purge: Air purged automatically before and after each sample;
duration automatically compensates for varying intake line lengths
Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses
Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Power requirements (Hz):
50 - 60 Hz
Power requirements (Voltage):
115 V
Power supply:
115 V
Probes included:
No
Rain Gauge Input:
No
Sample Container:
1 - 5.5 Gallon
Sensor Ports:
No
Sensors:
None
Special Features:
With Lock
Tubing:
Vinyl - 25', 3/8" ID x 5/8" OD tubing and PTFE/stainless steel strainer
Warranty:
12 months
Weight:
86 kg
What's included?:
1 ea. AS950 controller on 115V All Weather base
1 ea. Bottle kit (AW010060) includes 1- 5.5 gallon poly bottle w/cap (6494), composite tube support (8838) and full bottle shut-off (8847)
1 ea. 25' vinyl intake tubing (920)
1 ea. strainer (926)