5500sc Silica Analyser, 6 channels, reagents included

5500sc Silica Analyser, 6 channels, reagents included
Product #: 5500.KTO.S0.A6U
Unit Price Contact Hach

90 Days of Continuous Run Time

Only two liters of reagent are required for the analyzer to perform unattended for up to 90 days; twice as long as the Series 5000.

Save Time on Maintenance

The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps.

Avoid Downtime

Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime.

Clean, Fast and Easy Reagent Change

No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently.

Verify Easily with Hach Lab Products So You Don't Waste Time Second-guessing

Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.

What's included?

Hach 5500sc Analyser, reagents set for up to 90 days of use, installation kit, Hach user manuals

Specifications

Accuracy: 0–500 µg/L: ±1% or ±1 µg/L of reading, whichever is greater; 500–5000 µg/L: ±5%
Alarm: Four relays output; type: not powered SPDT relays, each rated at
5 A resistive, 240 VAC maximum
Connection: 18 to 14 AWG wire, 18 AWG stranded recommended
Application: Pure water / Power
Certifications: CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 )
KC (EN 61326-1: 2006)
C-tick (EN 61326-1: 2006)
cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
Controller Compatibility: SC200, SC1000
Enclosure rating: IP56 / NEMA 4X
Fitting: Sample line and sample bypass drain: 6 mm (¼-in.)
Air purge inlet: 6 mm (¼-in.)
Grab Sample: Grab Sample In and Grab Sample Out capability
Light source: Class 1M LED (light emitting diode) with a peak
wavelength of 810 nm
Lower Limit of Detection (LOD): 0.5 µg/L
Manual Languages: English
French
Spanish
B. Portuguese
Chinese
Japanese
Korean
Thai
German
Italian
C. Portuguese
Czech
Danish
Dutch
Polish
Swedish
Finnish
Bulgarian
Hungarian
Romanian
Lithuanian
Russian
Turkish
Slovak
Slovenian
Croatian
Greek
Estonian
Measuring Principle: Colorimetric
Measuring range: 0 - 5000 µg/L as SiO2
Mounting: Wall, panel or table
Number of Channels: 6
Operating Humidity: 5 - 95 % non-condensing (indoor use only)
Operating temperature range: 5 - 45 °C
Outputs: 4 - 20 mA (4x)
Parameter: Silica
Pollution Degree: 2/II
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 100 - 240 VAC
Protection Class: I
Reagent Consumption: 2 L of each reagent every 90 days with 15 minute cycle time
Relays: Four; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum
Repeatability: ± 0.5 µg/L or ± 1 % of reading, whichever is greater
Response time: Typically, 9.5 minutes at 25 °C (77 °F); changes with temperature
Sample Flow Rate: 55 - 300 mL/min
Sample Pressure: 2 - 87 psi (to Preset Pressure Regulator)
Sample Temperature: 5 - 50 °C (41 - 122°F)
Storage conditions: -20 - 60 °C
Warranty: 12 months
Weight: 20 kg (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents
What's included?: Hach 5500sc Analyser, reagents set for up to 90 days of use, installation kit, Hach user manuals